The objectives of the current test program include validation of predictions from the Massachusetts Institute of Technology (MIT) Atmospheric Fluidized Bed Coal Combustor System Model, continuation of experimental studies supporting AFBC process development, and collection of transient data for later process control studies. This topical report summarizes results from hot mode testing, i.e., experiments performed with combustion in the Process Development Unit for Model verification. During these tests, coal and limestone were fluidized and combusted with air at temperatures ranging from 1400 to 1580/sup 0/F in the 3'x 3'(nominal) size Process Development Unit (PDU) at Alexandria, Virginia. MIT Model predictions tested include: combustion efficiency, carbon loading, gas and solids concentrations, bed temperature, expanded bed height, overall heat transfer coefficient and sulfur retention by the coal/limestone system. Although not corresponding exactly, the Model predictions and experimental values for the overall heat transfer coefficients were relatively close in agreement. In all other cases, there were some discrepancies between the Model predictions and corresponding experimental PDU results. Transient process data were collected by the Data Acquisition System (DAS). Six parameters were recorded continuously on a six channel recorder. Variances were observed in the recorded transient data in response to input step changes.