Data from USGS National Water Quality Laboratory methods used to calculate and compare detection limits estimated using single- and multi-concentration spike-based and blank-based procedures

This dataset provides the expected and determined concentrations of selected inorganic and organic analytes for spiked reagent-water samples (calibration standards and limit of quantitation standards) that were used to calculate detection limits by using the United States Environmental Protection Agency’s (USEPA) Method Detection Limit (MDL) version 1.11 or 2.0 procedures, ASTM International’s Within-Laboratory Critical Level standard procedure D7783-13, and, for five pharmaceutical compounds, by USEPA’s Lowest Concentration Minimum Reporting Level procedure. Also provided are determined concentration data for reagent-water laboratory blank samples, classified as either instrument blank or set blank samples, and reagent-water blind-blank samples submitted by the USGS Quality System Branch, that were used to calculate blank-based detection limits by using the USEPA MDL version 2.0 procedure or procedures described in National Water Quality Laboratory Technical Memorandum 2016.02, http://wwwnwql.cr.usgs.gov/tech_memos/nwql.2016-02.pdf. The determined detection limits are provided and compared in the related external publication at https://doi.org/10.1016/j.talanta.2021.122139.

Data and Resources

Field Value
accessLevel public
bureauCode {010:12}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
identifier USGS:5f2c647882ceae4cb3c2d073
metadata_type geospatial
modified 20210331
old-spatial -105.135, 39.705, -105.115, 39.725
publisher U.S. Geological Survey
publisher_hierarchy Department of the Interior > U.S. Geological Survey
resource-type Dataset
source_datajson_identifier true
source_hash 075e1a0546379666308b5f86383acbc232c116a6
source_schema_version 1.1
spatial {"type": "Polygon", "coordinates": [[[-105.135, 39.705], [-105.135, 39.725], [ -105.115, 39.725], [ -105.115, 39.705], [-105.135, 39.705]]]}
theme {geospatial}
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • blank-sample
  • calibration-standard
  • chemical-analysis
  • ckan
  • concentration
  • environment
  • geo
  • geoss
  • laboratory-methods
  • limit-of-quantitation-standard
  • national
  • north-america
  • united-states
  • usgs-5f2c647882ceae4cb3c2d073
isopen False
license_id notspecified
license_title License not specified
maintainer William T Foreman
maintainer_email wforeman@usgs.gov
metadata_created 2025-11-21T12:47:39.673058
metadata_modified 2025-11-21T12:47:39.673062
notes This dataset provides the expected and determined concentrations of selected inorganic and organic analytes for spiked reagent-water samples (calibration standards and limit of quantitation standards) that were used to calculate detection limits by using the United States Environmental Protection Agency’s (USEPA) Method Detection Limit (MDL) version 1.11 or 2.0 procedures, ASTM International’s Within-Laboratory Critical Level standard procedure D7783-13, and, for five pharmaceutical compounds, by USEPA’s Lowest Concentration Minimum Reporting Level procedure. Also provided are determined concentration data for reagent-water laboratory blank samples, classified as either instrument blank or set blank samples, and reagent-water blind-blank samples submitted by the USGS Quality System Branch, that were used to calculate blank-based detection limits by using the USEPA MDL version 2.0 procedure or procedures described in National Water Quality Laboratory Technical Memorandum 2016.02, http://wwwnwql.cr.usgs.gov/tech_memos/nwql.2016-02.pdf. The determined detection limits are provided and compared in the related external publication at https://doi.org/10.1016/j.talanta.2021.122139.
num_resources 2
num_tags 16
title Data from USGS National Water Quality Laboratory methods used to calculate and compare detection limits estimated using single- and multi-concentration spike-based and blank-based procedures