Development of a Downhole Tool Measuring Real-Time Concentration of Ionic Tracers and pH in Geothermal Reservoirs

For enhanced or Engineered Geothermal Systems (EGS) geothermal brine is pumped to the surface via the production wells, the heat extracted to turn a turbine to generate electricity, and the spent brine re-injected via injection wells back underground. If designed properly, the subsurface rock formations will lead this water back to the extraction well as heated brine. Proper monitoring of these geothermal reservoirs is essential for developing and maintaining the necessary level of productivity of the field. Chemical tracers are commonly used to characterize the fracture network and determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data at very low levels of detection, it does not provide information regarding the location of the fractures which were conducting the tracer between wellbores. Sandia is developing a high-temperature electrochemical sensor capable of measuring tracer concentrations and pH downhole on a wireline tool. The goal of this effort is to collect real-time pH and ionic tracer concentration data at temperatures up to 225 degrees C and pressures up to 3000 psi.

In this paper, a prototype electrochemical sensor and the initial data obtained will be presented detailing the measurement of iodide tracer concentrations at high temperature and pressure in a newly developed laboratory scale autoclave.

Data and Resources

Additional Info

Field Value
Maintainer Grzegorz Cieslewski
Last Updated August 12, 2022, 04:18 (CDT)
Created August 12, 2022, 04:18 (CDT)
Identifier https://data.openei.org/submissions/3231
Issued 2014-03-31T06:00:00Z
Modified 2017-06-22T17:20:41Z
accessLevel public
bureauCode {019:20}
catalog_@context https://openei.org/data.json
catalog_@id https://openei.org/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
dataQuality true
landingPage https://gdr.openei.org/submissions/413
license https://creativecommons.org/licenses/by/4.0/
old-spatial {"type":"Polygon","coordinates":[[[-106.78560039063,34.931207062739],[-106.478084375,34.931207062739],[-106.478084375,35.14170232763],[-106.78560039063,35.14170232763],[-106.78560039063,34.931207062739]]]}
programCode {019:006}
projectLead Greg Stillman
projectNumber FY14 AOP 1.1.5.1
projectTitle High Temperature Chemical Sensing Tool for Distributed Mapping of Fracture Flow in EGS
publisher Sandia National Laboratories
resource-type Dataset
source_datajson_identifier true
source_hash 8a588540c1073020c63c82ae374f1915e3d6f7e7
source_schema_version 1.1
spatial {"type":"Polygon","coordinates":[[[-106.78560039063,34.931207062739],[-106.478084375,34.931207062739],[-106.478084375,35.14170232763],[-106.78560039063,35.14170232763],[-106.78560039063,34.931207062739]]]}