Extreme-Precision MEMS Segmented Deformable Mirror, Phase II

In Phase I research, Iris AO developed enhanced electromechanical models and calibration techniques for MEMS-based segmented deformable mirrors (DMs) applicable to a variety of high contrast astrophysical imagers. High-precision DMs with 1,000-1,000,000 actuators are critical for high-contrast systems. Non-MEMS DMs meet some NASA requirements, but require high actuation voltages, have low actuator densities, and do not scale readily beyond a few thousand actuators. MEMS DMs offer natural scalability, but do not yet meet the stringent precision and stability requirements for space telescopes. Prior to this Phase I work, very few researchers have focused on extremely precise characterization of MEMS DMs. Technical advances achieved in this Phase I improved open-loop positioning accuracy from nearly 100 nm rms to an impressive 8 nm rms. Stability measurements showed performance as good as 0.21-1.17 nm rms in an uncontrolled open-access laboratory over a 15-minute span. Including high-frequency noise sources not captured by Phase I optical measurement techniques but known to be present on the DM segments, this rises to 5.6 nm rms. Noise source analysis conducted in Phase I shows that stability to <0.2 nm rms is feasible. Phase II will implement the improvements necessary to attain <0.3 nm rms stability and resolution. These improvements include: 1) reducing known noise and drift sources identified in Phase I and tracking remaining measured but unknown noise sources; 2) increasing resolution to 0.14 nm rms through enhancements in drive electronics initiated in Phase I and optimizing the DM design to utilize the full dynamic range of the electronics; 3) improving optical quality of the Iris AO DM segments to 1-3 nm rms; 4) testing resolution and stability of the prototypes; 5) expanding reliability testing that started in Phase I and 6) investigate the effects of operating in vacuum.

Data and Resources

Field Value
accessLevel public
bureauCode {026:00}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_@id https://data.nasa.gov/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
identifier TECHPORT_6024
issued 2009-01-01
landingPage https://techport.nasa.gov/view/6024
modified 2020-01-29
programCode {026:027}
publisher Space Technology Mission Directorate
resource-type Dataset
source_datajson_identifier true
source_hash 8e73628e9c5e0e28ba6e0986a7a06db569a4d813
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • ckan
  • completed
  • geo
  • geoss
  • goddard-space-flight-center
  • national
  • north-america
  • united-states
isopen False
license_id notspecified
license_title License not specified
maintainer TECHPORT SUPPORT
maintainer_email hq-techport@mail.nasa.gov
metadata_created 2025-11-20T20:27:29.517803
metadata_modified 2025-11-20T20:27:29.517807
notes In Phase I research, Iris AO developed enhanced electromechanical models and calibration techniques for MEMS-based segmented deformable mirrors (DMs) applicable to a variety of high contrast astrophysical imagers. High-precision DMs with 1,000-1,000,000 actuators are critical for high-contrast systems. Non-MEMS DMs meet some NASA requirements, but require high actuation voltages, have low actuator densities, and do not scale readily beyond a few thousand actuators. MEMS DMs offer natural scalability, but do not yet meet the stringent precision and stability requirements for space telescopes. Prior to this Phase I work, very few researchers have focused on extremely precise characterization of MEMS DMs. Technical advances achieved in this Phase I improved open-loop positioning accuracy from nearly 100 nm rms to an impressive 8 nm rms. Stability measurements showed performance as good as 0.21-1.17 nm rms in an uncontrolled open-access laboratory over a 15-minute span. Including high-frequency noise sources not captured by Phase I optical measurement techniques but known to be present on the DM segments, this rises to 5.6 nm rms. Noise source analysis conducted in Phase I shows that stability to <0.2 nm rms is feasible. Phase II will implement the improvements necessary to attain <0.3 nm rms stability and resolution. These improvements include: 1) reducing known noise and drift sources identified in Phase I and tracking remaining measured but unknown noise sources; 2) increasing resolution to 0.14 nm rms through enhancements in drive electronics initiated in Phase I and optimizing the DM design to utilize the full dynamic range of the electronics; 3) improving optical quality of the Iris AO DM segments to 1-3 nm rms; 4) testing resolution and stability of the prototypes; 5) expanding reliability testing that started in Phase I and 6) investigate the effects of operating in vacuum.
num_resources 4
num_tags 10
title Extreme-Precision MEMS Segmented Deformable Mirror, Phase II