The high-temperature moving bed granular filter (GBF) program at Combustion Power Company (CPC) commenced in 1977. Its purpose was to investigate, for the Department of Energy, the filtration performance of the GBF for application to coal-fired PFBC turbine systems. The GBF test system was successfully operated on 1500/sup 0/F to 1600/sup 0/F gases produced from an atmospheric pressure coal-fired fluidized bed combustor. Overall collection efficiencies above 99% and submicron collection efficiencies above 96% were consistently demonstrated in over 1500 hours of high-temperature testing. Alkali content of the hot gases was also measured to evaluate aluminosilicate additives for controlling alkali emissions. Operational and performance stability under upset conditions (ten times normal inlet loading and 125% of design gas flowrate) was also demonstrated experimentally. A computer-based GBF performance model was developed. It predicts overall particle capture within - 5%. Gas flow streamlines and isobars are computer generated from theoretical principles and particle capture is based on the most recent empirical models. The effects of elevated pressure on efficiency and filter pressure drop are included in the model. A modular approach was adopted for GBF scale-up to commercial size systems using elements of the same size tested in this program. Elements can be readily packaged into 30,000 acfm modules at a projected equipment cost of approximately $27 per acfm.