High-Temp Component Evaluation.pdfPDF
Report of high temperature flash and tantalum capacitor evaluations beyond...
| Field | Value |
|---|---|
| accessLevel | public |
| bureauCode | {019:20} |
| catalog_@context | https://openei.org/data.json |
| catalog_@id | https://openei.org/data.json |
| catalog_conformsTo | https://project-open-data.cio.gov/v1.1/schema |
| catalog_describedBy | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
| dataQuality | true |
| identifier | https://data.openei.org/submissions/3372 |
| issued | 2015-10-28T06:00:00Z |
| landingPage | https://gdr.openei.org/submissions/612 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2017-07-18T19:52:31Z |
| old-spatial | {"type":"Polygon","coordinates":[[[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557]]]} |
| programCode | {019:006} |
| projectLead | Lauren Boyd |
| projectNumber | FY15 AOP 1.5.3.3 |
| projectTitle | Evaluation of High Temperature Components for Use in Geothermal Tools |
| publisher | Sandia National Laboratories |
| resource-type | Dataset |
| source_datajson_identifier | true |
| source_hash | 2a70db4cc6a080174395cbb348914e575d662525 |
| source_schema_version | 1.1 |
| spatial | {"type":"Polygon","coordinates":[[[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557],[-106.58386230469,35.045288404557]]]} |
| Groups |
|
| Tags |
|
| isopen | True |
| license_id | cc-by |
| license_title | Creative Commons Attribution |
| license_url | http://www.opendefinition.org/licenses/cc-by |
| maintainer | Avery Cashion |
| maintainer_email | atcashi@sandia.gov |
| metadata_created | 2025-11-20T01:22:03.605636 |
| metadata_modified | 2025-11-20T01:22:03.605640 |
| notes | Pushing the boundaries with geothermal tool development can often necessitate exceeding manufacturer specifications for temperature and pressure of individual circuit components. Detailed here are the efforts surrounding geothermal temperature characterization of commercially available HT-Flash memory modules made by Texas Instruments (SM28VLT32-HT) and preliminary results of 3 commercial solid tantalum capacitors. Flash evaluation boards were modified for high temperature application and read, write and erase functionality were tracked as well as prolonged data retention at various temperatures well beyond datasheet specifications. |