Indoor Air Concentrations of Quartz Fiber Filter-Collected Ionic PFAS June 2024

Summary statistics of indoor and outdoor collected ionic PFAS where values have been mean field blank subtracted. n.d. indicates non-detect and values with a “<” in front indicate that that PFAS was detected but at concentrations below the MDL. Concentrations below the MDL were not adjusted.

This dataset is associated with the following publication: Chang, N., C. Eichler, D. Amparo, J. Zhou, K. Baumann, E. Cohen-Hubal, J. Surratt, G. Morrison, and B. Turpin. Indoor air concentrations of PM2.5 quartz fiber filter-collected ionic PFAS and emissions to outdoor air: findings from the IPA campaign. Environmental Science: Processes & Impacts. Royal Society of Chemistry, Cambridge, UK, 27(6): 1603-1618, (2025).

Data and Resources

Field Value
accessLevel public
bureauCode {020:00}
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
identifier https://doi.org/10.23719/1532004
license https://pasteur.epa.gov/license/sciencehub-license-non-epa-generated.html
modified 2024-06-03
programCode {020:000}
publisher U.S. EPA Office of Research and Development (ORD)
publisher_hierarchy U.S. Government > U.S. Environmental Protection Agency > U.S. EPA Office of Research and Development (ORD)
references {https://doi.org/10.1039/d4em00359d,https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11965442}
resource-type Dataset
source_datajson_identifier true
source_hash 7a46e405bc28f30c89adee2ed3fa9d7f9787866c0b2ebb6d9b1bb777d48568d1
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • AmeriGEO
  • AmeriGEOSS
  • CKAN
  • GEO
  • GEOSS
  • National
  • North America
  • United States
  • indoor-air
  • indoor-chemistry
  • indoor-environment
  • pfas
isopen False
license_id other-license-specified
license_title other-license-specified
maintainer Elaine Cohen Hubal
maintainer_email cohenhubal.elaine@epa.gov
metadata_created 2025-09-24T16:56:14.160454
metadata_modified 2025-09-24T16:56:14.160464
notes Summary statistics of indoor and outdoor collected ionic PFAS where values have been mean field blank subtracted. n.d. indicates non-detect and values with a “<” in front indicate that that PFAS was detected but at concentrations below the MDL. Concentrations below the MDL were not adjusted. This dataset is associated with the following publication: Chang, N., C. Eichler, D. Amparo, J. Zhou, K. Baumann, E. Cohen-Hubal, J. Surratt, G. Morrison, and B. Turpin. Indoor air concentrations of PM2.5 quartz fiber filter-collected ionic PFAS and emissions to outdoor air: findings from the IPA campaign. Environmental Science: Processes & Impacts. Royal Society of Chemistry, Cambridge, UK, 27(6): 1603-1618, (2025).
num_resources 1
num_tags 12
title Indoor Air Concentrations of Quartz Fiber Filter-Collected Ionic PFAS June 2024