Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support
Data and Resources
-
My Design - PV.xmlXML
BEopt (v 2.0.0.6) design output.
-
Completed front elevation 2.jpgJPEG
Front elevation of the test house.
-
Mini-Split Heat Pump Evaluation and Zero...PDF
DOE Report
-
TO5 3.3.3_Monitoring Data.datdat
Monitoring data - time series
-
TO5 3.3.3_BEopt.BEopt.beoptbeopt
This is the BEopt file for the 2013 Imagine Test House. Version 2.2.0.1 was...
| Field | Value |
|---|---|
| DOI | 10.25984/2204237 |
| accessLevel | public |
| bureauCode | {019:20} |
| catalog_@context | https://openei.org/data.json |
| catalog_@id | https://openei.org/data.json |
| catalog_conformsTo | https://project-open-data.cio.gov/v1.1/schema |
| catalog_describedBy | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
| dataQuality | true |
| identifier | https://data.openei.org/submissions/5270 |
| issued | 2016-04-27T06:00:00Z |
| landingPage | https://data.openei.org/submissions/5270 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2023-11-01T16:41:17Z |
| old-spatial | {"type":"Polygon","coordinates":[[[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252]]]} |
| programCode | {019:002,019:000} |
| projectNumber | FY16 AOP 1.9.1.19 |
| projectTitle | Building America |
| publisher | Ibacos Innovation |
| resource-type | Dataset |
| source_datajson_identifier | true |
| source_hash | aac048a895c2879d578ac72a6194d1639e2549f51f62d53bb2f7bfd4c6976a20 |
| source_schema_version | 1.1 |
| spatial | {"type":"Polygon","coordinates":[[[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252],[-98.4946,29.4252]]]} |
| Groups |
|
| Tags |
|
| isopen | True |
| license_id | cc-by |
| license_title | Creative Commons Attribution |
| license_url | http://www.opendefinition.org/licenses/cc-by |
| maintainer | Ari Rapport |
| maintainer_email | arapport@ibacos.com |
| metadata_created | 2025-09-23T16:22:29.605191 |
| metadata_modified | 2025-09-23T16:22:29.605203 |
| notes | This project was created from a partnership between the U.S. Department of Energy's (DOE's) Building America research team, IBACOS, Inc., and a production builder of high-performance homes called Imagine Homes, which is located in San Antonio, Texas-a hot-humid climate. The primary purpose of this project was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system in maintaining uniform comfort in an occupied test house. My Design - PV: Test house design characteristics, with installed PV system DESIGN - Occupied Test House with PV: Design used for one occupied test house including PV STRUCTURE - Platinum Court San Antonio, TX: Occupied test house in 2013 |
| num_resources | 5 |
| num_tags | 19 |
| title | Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support |