Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers, Phase II
Data and Resources
-
Miniature Loop Heat Pipe with Multiple...HTML
Techport Project Page
-
Miniature Loop Heat Pipe with Multiple...HTML
Techport Project JSON Metadata
-
Miniature Loop Heat Pipe with Multiple...HTML
Techport Project XML Metadata
-
Miniature Loop Heat Pipe with Multiple...HTML
Techport Project PDF Export
| Field | Value |
|---|---|
| accessLevel | public |
| bureauCode | {026:00} |
| catalog_@context | https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld |
| catalog_@id | https://data.nasa.gov/data.json |
| catalog_conformsTo | https://project-open-data.cio.gov/v1.1/schema |
| catalog_describedBy | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
| identifier | TECHPORT_6520 |
| issued | 2009-02-01 |
| landingPage | https://techport.nasa.gov/view/6520 |
| modified | 2020-01-29 |
| programCode | {026:027} |
| publisher | Space Technology Mission Directorate |
| resource-type | Dataset |
| source_datajson_identifier | true |
| source_hash | df073a299399355f1ab13db61a3291cf9a96657c |
| source_schema_version | 1.1 |
| Groups |
|
| Tags |
|
| isopen | False |
| license_id | notspecified |
| license_title | License not specified |
| maintainer | TECHPORT SUPPORT |
| maintainer_email | hq-techport@mail.nasa.gov |
| metadata_created | 2025-11-21T08:11:50.733720 |
| metadata_modified | 2025-11-21T08:11:50.733724 |
| notes | Loop Heat Pipe (LHP) is a high performance heat transport device using capillary forces to circulate the working fluid in a closed loop. Conventional LHPs usually have one capillary pump (evaporator) to acquire waste heat from a heat source. Recent efforts have focused the development of LHPs that contain two or more evaporators. Even though two-evaporator LHPs performed very well, the volume of each compensation chamber (CC) became much larger than that of the single-evaporator counterpart. The reason was that all but one CC would be liquid-filled during normal operation. The one that was not liquid-filled had to be large enough to accommodate the system liquid expansion at maximum temperature. As a result, LHPs with more than 3 evaporators were not feasible for practical applications simply because the CCs became prohibitively large. In the current research, the CCs of a multiple-evaporator LHP were capillarily-linked. In other words, the CCs always contained a mixture of liquid and vapor (two-phase), allowing the loop to operate with a much smaller fluid charge. Consequently the required CC volume was also reduced. |
| num_resources | 4 |
| num_tags | 10 |
| title | Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers, Phase II |