Newberry EGS Demonstration Report: Repairing and Re-stimulating Well 55-29

The Newberry Volcano EGS Demonstration in central Oregon, a 5 year project begun in 2010, tests recent technological advances designed to reduce the cost of power generated by EGS in a hot, dry well (NWG 55-29) drilled in 2008. First, the stimulation pumps used were designed to run for weeks and deliver large volumes of water at moderate well-head pressure. Second, to stimulate multiple zones, AltaRock developed thermo-degradable zonal isolation materials (TZIMs) to seal off fractures in a geothermal well to stimulate secondary and tertiary fracture zones. The TZIMs degrade within weeks, resulting in an optimized injection/ production profile of the entire well. Third, the project followed a project-specific Induced Seismicity Mitigation Plan (ISMP) to evaluate, monitor for, and mitigate felt induced seismicity. An initial stimulation was conducted in 2012 and continued for 7 weeks, with over 41,000 m3 of water injected. Further analysis indicated a shallow casing leak and an unstable formation in the open hole. The well was repaired with a shallow casing tieback and perforated liner in the open hole and re-stimulated in 2014. The second stimulation started September 23rd, 2014 and continued for 3 weeks with over 9,500 m3 of water injected. The well was treated with several batches of newly tested TZIM diverter materials and a newly designed Diverter Injection Vessel Assembly (DIVA), which was the main modification to the original injection system design used in 2012. A second round of stimulation that included two perforation shots and additional batches of TZIM was conducted on November 11th, 2014 for 9 days with an additional 4,000 m3 of water injected. The stimulations resulted in a 3-4 fold increase in injectivity, and PTS data indicates partial blocking and creation of flow zones near the bottom of the well.

Data and Resources

Field Value
accessLevel public
bureauCode {019:20}
catalog_@context https://openei.org/data.json
catalog_@id https://openei.org/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
dataQuality true
identifier https://data.openei.org/submissions/3477
issued 2015-07-03T06:00:00Z
landingPage https://gdr.openei.org/submissions/775
license https://creativecommons.org/licenses/by/4.0/
modified 2019-11-14T21:59:22Z
old-spatial {"type":"Polygon","coordinates":[[[-121.4333333,43.51666667],[-121.0333333,43.51666667],[-121.0333333,43.91666667],[-121.4333333,43.91666667],[-121.4333333,43.51666667]]]}
programCode {019:006}
projectLead Lauren Boyd
projectNumber EE0002777
projectTitle Newberry EGS Demonstration
publisher AltaRock Energy Inc
resource-type Dataset
source_datajson_identifier true
source_hash bfe3f83f6db7dea6dc12367a85e24c1d4595632c
source_schema_version 1.1
spatial {"type":"Polygon","coordinates":[[[-121.4333333,43.51666667],[-121.0333333,43.51666667],[-121.0333333,43.91666667],[-121.4333333,43.91666667],[-121.4333333,43.51666667]]]}
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • ckan
  • demonstration
  • diverter-material
  • egs
  • geo
  • geoss
  • geothermal
  • groundwater-monitoring
  • hydraulic
  • microseismic-monitoring
  • national
  • newberry
  • newgen
  • north-america
  • repair
  • stimulation
  • temperature-monitoring
  • united-states
  • well
isopen True
license_id cc-by
license_title Creative Commons Attribution
license_url http://www.opendefinition.org/licenses/cc-by
maintainer Trenton T. Cladouhos
maintainer_email tcladouhos@altarockenergy.com
metadata_created 2025-11-21T08:29:59.354543
metadata_modified 2025-11-21T08:29:59.354547
notes The Newberry Volcano EGS Demonstration in central Oregon, a 5 year project begun in 2010, tests recent technological advances designed to reduce the cost of power generated by EGS in a hot, dry well (NWG 55-29) drilled in 2008. First, the stimulation pumps used were designed to run for weeks and deliver large volumes of water at moderate well-head pressure. Second, to stimulate multiple zones, AltaRock developed thermo-degradable zonal isolation materials (TZIMs) to seal off fractures in a geothermal well to stimulate secondary and tertiary fracture zones. The TZIMs degrade within weeks, resulting in an optimized injection/ production profile of the entire well. Third, the project followed a project-specific Induced Seismicity Mitigation Plan (ISMP) to evaluate, monitor for, and mitigate felt induced seismicity. An initial stimulation was conducted in 2012 and continued for 7 weeks, with over 41,000 m3 of water injected. Further analysis indicated a shallow casing leak and an unstable formation in the open hole. The well was repaired with a shallow casing tieback and perforated liner in the open hole and re-stimulated in 2014. The second stimulation started September 23rd, 2014 and continued for 3 weeks with over 9,500 m3 of water injected. The well was treated with several batches of newly tested TZIM diverter materials and a newly designed Diverter Injection Vessel Assembly (DIVA), which was the main modification to the original injection system design used in 2012. A second round of stimulation that included two perforation shots and additional batches of TZIM was conducted on November 11th, 2014 for 9 days with an additional 4,000 m3 of water injected. The stimulations resulted in a 3-4 fold increase in injectivity, and PTS data indicates partial blocking and creation of flow zones near the bottom of the well.
num_resources 2
num_tags 21
title Newberry EGS Demonstration Report: Repairing and Re-stimulating Well 55-29