Optical Approach to Augment Current Float Sensing Method of Determining Cryogen Fluid Height Within a Tank, Phase I

Innovative Imaging and Research, a small technology development company, has teamed with the University of Southern Mississippi Instrument and Cryogenics Research Laboratory to integrate existing NASA Stennis Space Center heritage cryogen level monitoring technology with noncontact optical methods and advanced signal processing to create a 21st century liquid cryogen level measurement technique. We propose to place a fiber-optic laser range finder on the upper surface of a low pressure cryogen run tank and use the existing Hall effect float system as an optical target to reflect the light signal back to the range finder. We also propose combining measurements obtained with the fiber-optic range finder with those taken by the heritage system using a custom Kalman filter signal processing algorithm to reduce measurement noise and increase overall accuracy. Our optical technique has several advantages over the existing Hall effect method. It yields near continuous measurements and is not dependent on the location of individual sensors. It is based on an alternate physics approach and therefore yields completely independent results. The optical range finder instrument calibration is performed outside the tank, so test operation is not significantly impacted and run tanks do not need to be emptied. In addition, an optical fiber mounted on the upper surface of a cryogen tank does not present foreign object debris (FOD) concerns. During our Phase 1 STTR project we will demonstrate our concept in a university cryogen research laboratory using a commercial optical range finder. In Phase 2 we plan to demonstrate our concept with fiber-optic technology using the SSC Instrument Test Apparatus under a NASA Space Act Agreement. Our Phase 1 concept is at a technology readiness level (TRL) of 2. We expect to complete Phase 1 at a TRL of 4 and complete Phase 2 at a TRL of 6.

Data and Resources

Field Value
accessLevel public
bureauCode {026:00}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_@id https://data.nasa.gov/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
identifier TECHPORT_10381
issued 2012-02-01
landingPage https://techport.nasa.gov/view/10381
modified 2020-01-29
programCode {026:027}
publisher Space Technology Mission Directorate
resource-type Dataset
source_datajson_identifier true
source_hash c2d5b8fa49d296fe49c1c8b07dea01d148b65e89
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • ckan
  • completed
  • geo
  • geoss
  • national
  • north-america
  • stennis-space-center
  • united-states
isopen False
license_id notspecified
license_title License not specified
maintainer TECHPORT SUPPORT
maintainer_email hq-techport@mail.nasa.gov
metadata_created 2025-11-21T22:19:01.029391
metadata_modified 2025-11-21T22:19:01.029395
notes Innovative Imaging and Research, a small technology development company, has teamed with the University of Southern Mississippi Instrument and Cryogenics Research Laboratory to integrate existing NASA Stennis Space Center heritage cryogen level monitoring technology with noncontact optical methods and advanced signal processing to create a 21st century liquid cryogen level measurement technique. We propose to place a fiber-optic laser range finder on the upper surface of a low pressure cryogen run tank and use the existing Hall effect float system as an optical target to reflect the light signal back to the range finder. We also propose combining measurements obtained with the fiber-optic range finder with those taken by the heritage system using a custom Kalman filter signal processing algorithm to reduce measurement noise and increase overall accuracy. Our optical technique has several advantages over the existing Hall effect method. It yields near continuous measurements and is not dependent on the location of individual sensors. It is based on an alternate physics approach and therefore yields completely independent results. The optical range finder instrument calibration is performed outside the tank, so test operation is not significantly impacted and run tanks do not need to be emptied. In addition, an optical fiber mounted on the upper surface of a cryogen tank does not present foreign object debris (FOD) concerns. During our Phase 1 STTR project we will demonstrate our concept in a university cryogen research laboratory using a commercial optical range finder. In Phase 2 we plan to demonstrate our concept with fiber-optic technology using the SSC Instrument Test Apparatus under a NASA Space Act Agreement. Our Phase 1 concept is at a technology readiness level (TRL) of 2. We expect to complete Phase 1 at a TRL of 4 and complete Phase 2 at a TRL of 6.
num_resources 4
num_tags 10
title Optical Approach to Augment Current Float Sensing Method of Determining Cryogen Fluid Height Within a Tank, Phase I