Picometer-Resolution MEMS Segmented DM, Phase II
Data and Resources
-
Picometer-Resolution MEMS Segmented DM, Phase IIHTML
Techport Project Page
-
Picometer-Resolution MEMS Segmented DM, Phase IIHTML
Techport Project JSON Metadata
-
Picometer-Resolution MEMS Segmented DM, Phase IIHTML
Techport Project XML Metadata
-
Picometer-Resolution MEMS Segmented DM, Phase IIHTML
Techport Project PDF Export
| Field | Value |
|---|---|
| accessLevel | public |
| bureauCode | {026:00} |
| catalog_@context | https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld |
| catalog_@id | https://data.nasa.gov/data.json |
| catalog_conformsTo | https://project-open-data.cio.gov/v1.1/schema |
| catalog_describedBy | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
| identifier | TECHPORT_9371 |
| issued | 2017-09-01 |
| landingPage | https://techport.nasa.gov/view/9371 |
| modified | 2020-01-29 |
| programCode | {026:027} |
| publisher | Space Technology Mission Directorate |
| resource-type | Dataset |
| source_datajson_identifier | true |
| source_hash | e3d7a9350e54044c5362e7ba2dec9508e23b1792 |
| source_schema_version | 1.1 |
| Groups |
|
| Tags |
|
| isopen | False |
| license_id | notspecified |
| license_title | License not specified |
| maintainer | TECHPORT SUPPORT |
| maintainer_email | hq-techport@mail.nasa.gov |
| metadata_created | 2025-11-19T17:36:29.077466 |
| metadata_modified | 2025-11-19T17:36:29.077471 |
| notes | Microelectromechanical systems (MEMS) technology has the potential to create deformable mirrors (DM) with 10^4 actuators that have size, weight, and power specifications that are far lower than conventional piezoelectric and electrostrictive DMs. However, building a MEMS DM with a relatively large aperture that is flat in the unpowered state is challenging. Currently, a large portion of the mirror stroke must be used to flatten the MEMS DMs. In the case of the large-stroke segmented MEMS DMs manufactured by Iris AO, there is sufficient stroke for wavefront correction after flattening. However, the resolution is significantly reduced because the dynamic range of the digital-to-analog converters (DAC) used to operate the DM is spread over multiple microns of stroke rather than the 0.5 micron range required for a coronagraph. This Phase I SBIR will make substantial improvements in the fabrication process of MEMS segmented DMs that reduce the deleterious residual surface-figure errors. It will do so by systematically addressing the sources of the segment position variations as well as addressing low-spatial frequency chip bow that can result in large peak-to-valley deformations across the DM array. The Iris AO DM architecture will also be modified to enable picometer resolution actuation with ultra-precision drive electronics. |
| num_resources | 4 |
| num_tags | 10 |
| title | Picometer-Resolution MEMS Segmented DM, Phase II |