PV Inverter Experimental Dataset Version 2 with 100 Percent Power
Data and Resources
-
This file contains the experimental data from...BIN
This file contains the experimental data from voltage magnitude step change...
-
This file contains the dataset for changes in...BIN
This file contains the dataset for changes in frequency (controllable AC...
| Field | Value |
|---|---|
| accessLevel | public |
| bureauCode | {019:20} |
| catalog_@context | https://openei.org/data.json |
| catalog_@id | https://openei.org/data.json |
| catalog_conformsTo | https://project-open-data.cio.gov/v1.1/schema |
| catalog_describedBy | https://project-open-data.cio.gov/v1.1/schema/catalog.json |
| dataQuality | true |
| datagov_dedupe_retained | 20250120171954 |
| identifier | https://data.openei.org/submissions/8268 |
| issued | 2023-11-10T20:46:44Z |
| landingPage | https://data.nrel.gov/submissions/217 |
| license | https://creativecommons.org/licenses/by/4.0/ |
| modified | 2025-01-16T23:57:28Z |
| programCode | {019:023,019:000,019:008} |
| projectNumber | CPS agreement number - 38455 |
| projectTitle | Scalable Multi-Timescale Analysis Platform Based on System Transient and Dynamic Models |
| publisher | National Renewable Energy Laboratory |
| resource-type | Dataset |
| source_datajson_identifier | true |
| source_hash | 55c87ecfad915f1cbf8727adf03a82aca774f7d5be95dbdf4bf05ee6a0854e0e |
| source_schema_version | 1.1 |
| Groups |
|
| Tags |
|
| isopen | True |
| license_id | cc-by |
| license_title | Creative Commons Attribution |
| license_url | http://www.opendefinition.org/licenses/cc-by |
| maintainer | Kumaraguru Prabakar |
| maintainer_email | Kumaraguru.Prabakar@nrel.gov |
| metadata_created | 2025-09-23T19:55:13.270706 |
| metadata_modified | 2025-09-23T19:55:13.270713 |
| notes | The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset. |
| num_resources | 2 |
| num_tags | 20 |
| title | PV Inverter Experimental Dataset Version 2 with 100 Percent Power |