Rodent Centrifuge, Phase I

According to the decadal report titled, Life and Physical Sciences Research for a New Era of Space Exploration, a Report, ??the AHB Panel would be remiss if it did not strongly recommend an animal centrifuge capable of accommodating rats/mice at variable gravity levels.? Furthermore, the panel stated, ??research on animal models will be constrained without the ability to manipulate the gravity variable as a factor modulating the fundamental processes underlying organ system homeostasis.? In response, Techshot has proposed to develop a Rodent Centrifuge Facility (RCF-QL) that utilizes four locker locations (Quad Locker) in the EXPRESS Rack for life science research. The counter-balanced centrifuge is designed to provide a facility to allow rats and mice to live and be observed in simulated gravity between 0-1 g for up to 90 days. The RCF-QL provides up to five cages. Each cage can accommodate at least six 30 gram mice, three 200 gram rats, or two 400 gram rats per cage. Each individual cage has ablib food and water, controllable lighting, and video monitoring. The habitat is temperature controlled with constant airflow throughout the cages. Air flow entraps waste in a filter that also treats the waste for bacteria and odor. Additional air filters will remove odors and ammonium from the animal enclosure. The subsystems design will minimize crew time. Each subsystem requiring change-out during the 90 day experiment will be designed to be simple and intuitive in operations. The RCF-QL will be the only facility capable of providing group housing for rats and mice, with a medium diameter centrifuge (20 in., 0.508 m) and a large rotating cage volume (1000 in3, 16,400 cm3 for the cage). All hardware cage features are designed to meet NIH animal care and use standards.

Data and Resources

Field Value
accessLevel public
bureauCode {026:00}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_@id https://data.nasa.gov/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
identifier TECHPORT_93743
issued 2017-12-01
landingPage https://techport.nasa.gov/view/93743
modified 2020-01-29
programCode {026:027}
publisher Space Technology Mission Directorate
resource-type Dataset
source_datajson_identifier true
source_hash 8f578fb654fc24edfb8f7d56a83be0ed6bbbe1a1
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • active
  • amerigeo
  • amerigeoss
  • ames-research-center
  • ckan
  • geo
  • geoss
  • national
  • north-america
  • united-states
isopen False
license_id notspecified
license_title License not specified
maintainer TECHPORT SUPPORT
maintainer_email hq-techport@mail.nasa.gov
metadata_created 2025-11-19T17:34:45.857549
metadata_modified 2025-11-19T17:34:45.857555
notes According to the decadal report titled, Life and Physical Sciences Research for a New Era of Space Exploration, a Report, ??the AHB Panel would be remiss if it did not strongly recommend an animal centrifuge capable of accommodating rats/mice at variable gravity levels.? Furthermore, the panel stated, ??research on animal models will be constrained without the ability to manipulate the gravity variable as a factor modulating the fundamental processes underlying organ system homeostasis.? In response, Techshot has proposed to develop a Rodent Centrifuge Facility (RCF-QL) that utilizes four locker locations (Quad Locker) in the EXPRESS Rack for life science research. The counter-balanced centrifuge is designed to provide a facility to allow rats and mice to live and be observed in simulated gravity between 0-1 g for up to 90 days. The RCF-QL provides up to five cages. Each cage can accommodate at least six 30 gram mice, three 200 gram rats, or two 400 gram rats per cage. Each individual cage has ablib food and water, controllable lighting, and video monitoring. The habitat is temperature controlled with constant airflow throughout the cages. Air flow entraps waste in a filter that also treats the waste for bacteria and odor. Additional air filters will remove odors and ammonium from the animal enclosure. The subsystems design will minimize crew time. Each subsystem requiring change-out during the 90 day experiment will be designed to be simple and intuitive in operations. The RCF-QL will be the only facility capable of providing group housing for rats and mice, with a medium diameter centrifuge (20 in., 0.508 m) and a large rotating cage volume (1000 in3, 16,400 cm3 for the cage). All hardware cage features are designed to meet NIH animal care and use standards.
num_resources 4
num_tags 10
title Rodent Centrifuge, Phase I