Spectroscopic Dosimeter, Phase II

Analysis of Phase I test data demonstrates that the Photogenics Spectroscopic Dosimeter will detect neutron energies from 0.8 up to 600 MeV. The detector efficiencies in the energy region of interest to NASA of 0.5 to 150 MeV were predicted by MCNP-X models. These models were partially confirmed by the tests at the EAL and LANSCE, with a high confidence in the data for the 1-14 MeV range and a confirmation of the detector's spectroscopic capabilities between 15-150 MeV. Further analysis of the high energy data will be performed in Phase II. Using the detection efficiencies determined Phase I and the IRCP74 damage coefficients, doses have been calculated for the neutron fluxes encountered in the test facilities. During Phase II a full-scale working model of the spectroscopic dosimeter will be fabricated and tested.

Data and Resources

Field Value
accessLevel public
bureauCode {026:00}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_@id https://data.nasa.gov/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
identifier TECHPORT_7852
issued 2011-01-01
landingPage https://techport.nasa.gov/view/7852
modified 2020-01-29
programCode {026:027}
publisher Space Technology Mission Directorate
resource-type Dataset
source_datajson_identifier true
source_hash 3a342ace5bcee4df46453e25f4d53e29fbb82e81
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • ames-research-center
  • ckan
  • completed
  • geo
  • geoss
  • national
  • north-america
  • united-states
isopen False
license_id notspecified
license_title License not specified
maintainer TECHPORT SUPPORT
maintainer_email hq-techport@mail.nasa.gov
metadata_created 2025-11-22T19:32:17.408477
metadata_modified 2025-11-22T19:32:17.408481
notes Analysis of Phase I test data demonstrates that the Photogenics Spectroscopic Dosimeter will detect neutron energies from 0.8 up to 600 MeV. The detector efficiencies in the energy region of interest to NASA of 0.5 to 150 MeV were predicted by MCNP-X models. These models were partially confirmed by the tests at the EAL and LANSCE, with a high confidence in the data for the 1-14 MeV range and a confirmation of the detector's spectroscopic capabilities between 15-150 MeV. Further analysis of the high energy data will be performed in Phase II. Using the detection efficiencies determined Phase I and the IRCP74 damage coefficients, doses have been calculated for the neutron fluxes encountered in the test facilities. During Phase II a full-scale working model of the spectroscopic dosimeter will be fabricated and tested.
num_resources 4
num_tags 10
title Spectroscopic Dosimeter, Phase II