UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence O - Raw Data

Overview

Sequence O: Sin AOA, Parked (P)

This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the absence of rotational influences by varying blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 18.9 m/s to 39.3 m/s, and the yaw angle was 0° throughout the sequence. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N.

Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the OSU wind tunnel (Reuss Ramsey et al. 1995) as well as 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation O, followed by two digits for the span location (30, 47, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

Data Details

File naming information can be found in the attached Word document "Sequence O Filename Key", copied from the Phase VI Test Report.

Data and Resources

Field Value
DOI 10.21947/1483824
accessLevel public
bureauCode {019:20}
catalog_@context https://openei.org/data.json
catalog_@id https://openei.org/data.json
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
dataQuality true
identifier https://data.openei.org/submissions/4210
issued 2018-11-29T00:00:00Z
landingPage https://a2e.energy.gov/data/uae6/uae6.z14.00
license https://creativecommons.org/licenses/by/4.0/
modified 2020-03-27T00:00:00Z
programCode {019:010}
projectNumber 67025
projectTitle Wind Data Hub
publisher Wind Energy Technologies Office (WETO)
resource-type Dataset
source_datajson_identifier true
source_hash 574fb80eb69ceac80a07c1e641c3b5bb9d1cd459
source_schema_version 1.1
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • 00
  • a2e
  • amerigeo
  • amerigeoss
  • atmosphere-to-electrons
  • ckan
  • eere
  • geo
  • geoss
  • national
  • north-america
  • raw-data
  • sequence-o
  • uae6
  • united-states
  • unsteady-aerodynamics-experiment-phase-vi-nrel-nasa-ames-wind-tunnel-experiment
  • weto
  • wind
  • wind-tunnel-tests-data
  • z14
isopen True
license_id cc-by
license_title Creative Commons Attribution
license_url http://www.opendefinition.org/licenses/cc-by
maintainer Lee Fingersh
maintainer_email lee.fingersh@nrel.gov
metadata_created 2025-11-22T01:04:18.275631
metadata_modified 2025-11-22T01:04:18.275636
notes **Overview** Sequence O: Sin AOA, Parked (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the absence of rotational influences by varying blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 18.9 m/s to 39.3 m/s, and the yaw angle was 0° throughout the sequence. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the OSU wind tunnel (Reuss Ramsey et al. 1995) as well as 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation O, followed by two digits for the span location (30, 47, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity. **Data Details** File naming information can be found in the attached Word document "Sequence O Filename Key", copied from the Phase VI Test Report.
num_resources 1
num_tags 20
title UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence O - Raw Data