Hydrograph-separation results for 225 streams in the Chesapeake Bay watershed derived by using PART, HYSEP (Fixed, Local minimum, Slide), BFI, and a Recursive Digital Filter with streamflow data ranging from 1913 through 2016

This U.S. Geological Survey (USGS) data release contains daily-mean streamflow and estimated-daily base flow for 225 streamgages in the Chesapeake Bay watershed ranging from 1913 to 2016 (beginning and end dates may vary). There is a table containing hydrograph-separation results by six methods for 225 sites (Hydrograph_separation_results_for_225_streams_in_the_Chesapeake_Bay_watershed) and a summary table with hydrograph-separation results for each site and method (Hydrograph_separation_summary_for_225_streams_in_the_Chesapeake_Bay_watershed). Quantitative estimates of base flow are necessary to address questions of the vulnerability and response of aquatic ecosystems to natural and human-induced change in environmental conditions. Base flow is generally not measured directly, but is estimated from observations of streamflow and (or) stream water chemistry. Base flow was estimated using PART (Rutledge, 1998), HYSEP (Fixed, Local minimum, and Slide; Sloto and Crouse, 1996), BFI (Wahl and Wahl, 1988 and Wahl and Wahl, 1995), and a Recursive Digital Filter (Eckhardt, 2005 and Collishonn and Fan, 2013) in selected watersheds throughout the Chesapeake Bay watershed. The references to the above citations are in the Supplemental Information section of this metadata record. These data support the following publication: Raffensperger, J.P., Baker, A.C., Blomquist, J.D., and Hopple, J.A., 2017, Optimal hydrograph separation using a recursive digital filter constrained by chemical mass balance, with application to selected Chesapeake Bay watersheds: U.S. Geological Survey Scientific Investigations Report 2017-5034, 51 p., https://doi.org/10.3133/sir20175034.

Data and Resources

Field Value
accessLevel public
bureauCode {010:12}
catalog_@context https://project-open-data.cio.gov/v1.1/schema/catalog.jsonld
catalog_conformsTo https://project-open-data.cio.gov/v1.1/schema
catalog_describedBy https://project-open-data.cio.gov/v1.1/schema/catalog.json
datagov_dedupe_retained 20220721183729
identifier USGS:57f54fd1e4b0bc0bec050bf7
metadata_type geospatial
modified 20200825
old-spatial {"type": "Polygon", "coordinates": [[[-80.475978, 36.674013], [-80.475978, 42.972499], [ -74.588733, 42.972499], [ -74.588733, 36.674013], [-80.475978, 36.674013]]]}
publisher U.S. Geological Survey
publisher_hierarchy Department of the Interior > U.S. Geological Survey
resource-type Dataset
source_datajson_identifier true
source_hash d2f20ea51807a804d9d60ce906b9b01c37e40249
source_schema_version 1.1
spatial {"type": "Polygon", "coordinates": [[[-80.475978, 36.674013], [-80.475978, 42.972499], [ -74.588733, 42.972499], [ -74.588733, 36.674013], [-80.475978, 36.674013]]]}
theme {geospatial}
Groups
  • AmeriGEOSS
  • National Provider
  • North America
Tags
  • amerigeo
  • amerigeoss
  • base-flow
  • ckan
  • geo
  • geoss
  • groundwater
  • hydrograph-separation
  • national
  • north-america
  • united-states
  • usgs-57f54fd1e4b0bc0bec050bf7
isopen False
license_id notspecified
license_title License not specified
maintainer Jeff P. Raffensperger
maintainer_email jpraffen@usgs.gov
metadata_created 2025-11-20T22:51:01.996040
metadata_modified 2025-11-20T22:51:01.996044
notes This U.S. Geological Survey (USGS) data release contains daily-mean streamflow and estimated-daily base flow for 225 streamgages in the Chesapeake Bay watershed ranging from 1913 to 2016 (beginning and end dates may vary). There is a table containing hydrograph-separation results by six methods for 225 sites (Hydrograph_separation_results_for_225_streams_in_the_Chesapeake_Bay_watershed) and a summary table with hydrograph-separation results for each site and method (Hydrograph_separation_summary_for_225_streams_in_the_Chesapeake_Bay_watershed). Quantitative estimates of base flow are necessary to address questions of the vulnerability and response of aquatic ecosystems to natural and human-induced change in environmental conditions. Base flow is generally not measured directly, but is estimated from observations of streamflow and (or) stream water chemistry. Base flow was estimated using PART (Rutledge, 1998), HYSEP (Fixed, Local minimum, and Slide; Sloto and Crouse, 1996), BFI (Wahl and Wahl, 1988 and Wahl and Wahl, 1995), and a Recursive Digital Filter (Eckhardt, 2005 and Collishonn and Fan, 2013) in selected watersheds throughout the Chesapeake Bay watershed. The references to the above citations are in the Supplemental Information section of this metadata record. These data support the following publication: Raffensperger, J.P., Baker, A.C., Blomquist, J.D., and Hopple, J.A., 2017, Optimal hydrograph separation using a recursive digital filter constrained by chemical mass balance, with application to selected Chesapeake Bay watersheds: U.S. Geological Survey Scientific Investigations Report 2017-5034, 51 p., https://doi.org/10.3133/sir20175034.
num_resources 2
num_tags 12
title Hydrograph-separation results for 225 streams in the Chesapeake Bay watershed derived by using PART, HYSEP (Fixed, Local minimum, Slide), BFI, and a Recursive Digital Filter with streamflow data ranging from 1913 through 2016